Do Solar Panels Damage Your Roof? Leaks, Warranty, Risks

Do solar panels damage your roof? Not when mounts hit rafters and are flashed. Leak causes, warranty effects, and $200-$500 per panel removal cost.

Do solar panels damage your roof? Properly installed, they do not. Leaks tied to solar come from the 30 to 50 penetrations in a typical array, not the panels, so the roof’s remaining life (reroof first under 15 years) matters more than the array: when fasteners land in rafters and pass through flashing, they behave like a plumbing vent or skylight curb. The damage risk comes from bad workmanship: poorly sealed penetrations, mounts screwed into decking instead of framing, or a crew with no roofing experience.

Reviewed by The Roofing Brief Team. Last reviewed: October 2026.

Do solar panels damage a roof, or is that a myth?

A correctly installed rooftop solar array does not damage the roof, and the covered section is shielded from direct sun and hail. The panels, which last 25 to 30 years, sit on standoffs above the shingles, and the roof continues to shed water normally underneath all but the 30 to 50 flashed mounting points. Damage happens when the attachment is done wrong, not because a panel is bolted to your roof.

The confusion comes from a real fact: mounting a standard rooftop array means drilling holes in the roof. On an asphalt shingle roof, a typical residential system uses 30 to 50 roof penetrations, and each hole is a potential leak if it is not flashed and sealed correctly. Rooftop PV structural and fire-access rules sit in IRC Section R324, and mounting hardware is listed to UL 2703; for example, IronRidge’s IronRidge FlashFoot2 page lists an 8 by 12 inch flashing, a 25-year product warranty and a passed TAS-100 wind-driven rain test.

Do solar panels cause roof leaks?

Solar panels cause roof leaks only when the mounting penetrations are installed or sealed incorrectly. Three installation faults at the penetration point cause these leaks: lag bolts that miss the rafter and sit in 7/16-inch decking, missing flashing, and sealant-only seals. All three are avoidable.

  • Lag bolts missing the rafter. Mounting feet must hit solid framing. Screwed into 7/16-inch decking alone, they loosen, back out, and open the hole to water. This is the single most common solar leak cause.
  • No flashing over the penetration. A quality mount uses a metal flashing plate slipped under the shingle course above the hole, so water sheds over it. Skipping the flashing and relying on sealant alone fails within 3 to 5 years.
  • Sealant-only waterproofing. Butyl or asphalt sealant degrades in UV in roughly 3 to 5 years. When it is the only thing keeping water out, the hole leaks once the sealant cracks; sealant backs up the flashing and is never the primary barrier.

Leaks that show up 3 to 5 years after install usually mean sealant-only mounts that have aged out; leaks in the first storm usually mean a bolt missed the rafter or a flashing was omitted. Either way, the fix and the liability sit with the installer.

How solar panel roof penetrations should be installed

A correct solar penetration lands a lag bolt in the rafter (typically 16 or 24 inches on center), seals the hole, and covers it with a flashing that integrates into the shingle courses above, so it sheds water like any other roof detail. The corner-cutting version leaks.

Element Correct install Failure-prone shortcut
Attachment point Lag bolt into rafter or truss, located with a stud finder or from the attic Screwed into decking only, “wherever it lands”
Pilot hole Pre-drilled to bolt diameter, filled with sealant before the bolt goes in Bolt driven dry, splitting the rafter
Flashing Metal flashing slid under the course above so water sheds over it No flashing; sealant smeared over the shingle
Waterproofing Flashing primary, sealant secondary Sealant only, degrades in 3 to 5 years
Crew Installer with roofing experience or a roofer sub Solar electricians with no roofing background

Rail-less or bonded UL 2703-listed mounts reduce penetration counts, and flat commercial roofs often use ballasted racking that adds no holes at all. For a deeper look at penetration and flashing detail, see our guide on roof flashing and why it causes most leaks.

Do solar panels void your roof warranty?

In most cases solar panels do not void a roof warranty (shingle material warranties commonly run 25 to 50 years), as long as the installer follows the roofing manufacturer’s mounting and flashing instructions. The risk is specific: drilling into the roof can void the materials portion of some shingle warranties, because the manufacturer treats an unauthorized penetration as damage to the covered product. Read your own warranty for the exclusion wording and ask the maker whether it requires an approved mount or certified installer. On standing seam, our guide to solar panels on a metal roof covers clamp-on mounting.

There are usually three separate warranties in play on a roof-plus-solar project, and confusing them is where homeowners get burned:

  • Roofing material warranty. Covers shingle defects, typically 25 to 50 years. A penetration by an unaffiliated party can void coverage on the affected area. Some manufacturers require their own certified installer or an approved mount to keep it intact.
  • Roofing workmanship warranty. From the roofer who installed the roof, usually 2 to 10 years. Letting another trade drill into that roof often ends this coverage unless the roofer signs off.
  • Solar installer workmanship warranty. From the solar company, commonly 10 years, and this is the one that covers leaks caused by the panel mounts. If a penetration leaks, this warranty pays to fix the roof.

Before the panels go up, get written confirmation from the shingle maker or your roofer that the mounting method preserves the roof warranty, and get the solar workmanship warranty terms (commonly 10 years) for leak repair in writing. We break the three-warranty stack down in detail in our guide to solar roof warranties and what each one covers.

What does it cost to remove solar panels for a roof replacement?

Removing and reinstalling solar panels to replace the roof underneath runs about $200 to $500 per panel, per Fixr ($200 to $300) and HomeAdvisor ($200 to $500). Fixr puts a typical 14 to 16 panel residential system at $2,800 to $4,800; at HomeAdvisor’s $500 per panel upper end, the same 14 to 16 panels would cost $7,000 to $8,000. That is a real cost the panels add to any future reroof, and it is the strongest practical argument for replacing an aging roof before you go solar, not after. Panels last 25 to 30 years, so a roof with less than 15 years of life left is usually worth replacing first, and the DOE Homeowner’s Guide to Solar also tells owners to weigh roof age and replacement timing before installing. For permits, storage and who should do the work, see our full guide to removing solar panels for roof repair.

The R&R job runs in five steps, and anyone on the roof falls under fall-protection rules such as OSHA 1926.501:

  1. Disconnect and de-energize the system, done by a licensed electrician or the solar company.
  2. Remove panels and racking, label components, and store them safely off the roof.
  3. Tear off and replace the roof as a standard reroof, now with clear deck access.
  4. Remount racking with new flashing at fresh penetrations; old mount holes are covered by the new roof.
  5. Reconnect, commission, and inspect, including any utility or AHJ sign-off.

Combining removal with a planned reroof avoids paying $200 to $500 per panel a second time. See our related guides on mounting solar panels on a flat roof and solar shingles versus panels for how mounting choice changes future removal cost.

How to lower the roof damage risk before you install solar

You reduce solar roof damage risk mostly by vetting the solar company, since the crew and the roof’s condition matter more than the panels; under 15 years of remaining roof life changes the plan.

  • Reroof first if the roof has under 15 years left. It is cheaper than paying R&R costs later and starts your solar clock on a fresh deck.
  • Hire an installer with roofing experience, or one who subs the mounting to a licensed roofer. Know what a solar installation includes and ask directly who drills the 30 to 50 holes, because a 10-year solar workmanship warranty only helps if the right party made them.
  • Confirm flashed mounts, not sealant-only. Ask what mounting product they use and whether every penetration gets a metal flashing.
  • Get the warranty coordination in writing from both the roofer and the solar company before work starts.
  • Require a post-install roof inspection, ideally after the first heavy rain, so a leak is caught while the workmanship warranty is fresh.
If… Then
The roof has under 15 years of life left Reroof first; panels last 25 to 30 years and R&R costs $200 to $500 per panel
Quote shows lag bolts into rafters plus metal flashing at every foot Proceed; this is the spec in the table above
Quote says “sealant” and does not mention flashing Ask for flashed mounts in writing before signing
Your shingle warranty is still in force Get the roofer’s and manufacturer’s written sign-off on the mount
The roof is flat commercial Ask about ballasted racking, which adds no holes
A leak appears after install Call the solar installer; their workmanship warranty (commonly 10 years) covers it

Report any leak the moment you see it, because solar workmanship warranties (commonly 10 years) cover installer-caused leaks but delay lets water reach decking and drywall. For a broader grounding in roof systems, start with our learn hub on how roofs work.